Lux Products TX9600TSa Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Thermostats Lux Products TX9600TSa. Lux Products TX9600TSa Instruction Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CAUTIONS AND WARNINGS . . . . . . . . . . 2
SYSTEM COMPATIBILITY . . . . . . . . . . . . 3
FEATURES . . . . . . . . . . . . . . . . . . . . . . . 4
TOOLS YOU MAY NEED. . . . . . . . . . . . . . 4
MOUNTING LOCATION . . . . . . . . . . . . . . 5
REMOVE OLD THERMOSTAT . . . . . . . . . . 5
INSTALL THERMOSTAT BASE . . . . . . . . . 6
WIRING INFORMATION . . . . . . . . . . . . . . 7
WIRING DIAGRAMS . . . . . . . . . . . . . . . . 9
HARDWARE SETUP OPTIONS . . . . . . . . 18
COMPLETE THE INSTALL . . . . . . . . . . . 20
FRONT PANEL ITEMS . . . . . . . . . . . . . . 20
OPERATING INSTRUCTIONS . . . . . . . . . 21
TEMPERATURE PROGRAMS . . . . . . . . . 24
ADVANCED FEATURES . . . . . . . . . . . . . 25
BATTERY REPLACEMENT . . . . . . . . . . . 33
TECHNICAL ASSISTANCE . . . . . . . . . . . 34
LIMITED WARRANTY . . . . . . . . . . . . . . 34
MERCURY NOTICE . . . . . . . . . . . . . . . . 34
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Procter & Gamble Company
© 2013 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
TX9600TSa
SMART TEMP
®
UNIVERSAL
7-DAY PROGRAMMABLE TOUCHSCREEN THERMOSTAT
(FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS)
INSTALLATION AND OPERATING INSTRUCTIONS
IMPORTANT!
• Please read all of these instructions carefully before beginning
installation.
• Label every wire terminal designation on your existing thermostat wiring
before removing your old thermostat.
• Ignore the color of the wires since they may not comply with any
standard. Please connect wires using the terminal letter designations.
Thank you for your confidence in our product. To obtain the best results from
your investment, please read and follow the installation procedures carefully, and
one step at a time. This will save you time and minimize the chance of damaging
either the thermostat or possibly your heating and cooling system. These
instructions may contain information beyond that which may be required for your
particular installation.
52138
Vue de la page 0
1 2 3 4 5 6 ... 34 35

Résumé du contenu

Page 1 - TX9600TSa

CAUTIONS AND WARNINGS . . . . . . . . . . 2SYSTEM COMPATIBILITY . . . . . . . . . . . . 3FEATURES . . . . . . . . . . . . . . . . . . . . . . . 4TOOLS

Page 2

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICW2W14WXFGB*RHVRW2 A W1G B CO Y RC RH1-STAGE OR 2-STAGE, HEATING

Page 3

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICXB*CRHVR AW14WW2 A W1G B CO Y RC RHHOT WATER HEATING ONLY(WITH A

Page 4

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICXFGY16YB*RCVRW2 A W1G B CO Y RC RH1-STAGE, COOLING ONLYFactory R

Page 5

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICRHRCVRY16YFGXW14WB*W2 A COG BYRC RHCONVENTIONAL (NON HEAT PUMP)1

Page 6

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICW14WRHRCVRY16YFGXW2B*A W1 COG BYRC RHCONVENTIONAL (NON HEAT PUMP

Page 7

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICXB*CRVRHRVRCY16YFGW14WW2 A W1G B CO Y RC RHCONVENTIONAL (NON HEA

Page 8

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICXFGY16YOB*RCVRW2 A W1G B CO Y RC RHSINGLE-STAGE HEAT PUMP SYSTEM

Page 9

NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFICCUSTOMER INSTALLED Y-W1 Jumper WireXB*CW3WW2FGY16YORCVRW2 A W1G

Page 10 - W2 A W1G B CO Y RC RH

On the thermostat’s circuit board, there is a row of DIP switches, labeled #1through #7. The position of these switches will change how the thermosta

Page 11

SWITCH #4 (SCALE): [OFF/RIGHT = F, default] All temperature values aredisplayed using the Fahrenheit scale. [ON/LEFT = C] This setting displays allte

Page 12

• This thermostat requires batteries to operate and failure or sub-standardperformance of the batteries may impair or prevent the correct operation of

Page 13 - W2 A COG BYRC RH

GAS / ELEC SLIDE SWITCH (FAN OPERATION):This switch is a physical component by itself on thecircuit board, and is much larger than the DIPswitches lis

Page 14 - A W1 COG BYRC RH

NOTE: The Fan Mode switch only works if your system provides a wire for thethermostat’s “G” wire terminal, to control a blower fan. The Fan Mode swit

Page 15

There are on-screen indicators to show you when the thermostat is calling forheating or cooling to occur. In the Heat mode switch position, a flame w

Page 16

LCD DISPLAY BACKLIGHT: The display screen is lighted to assist viewing atnighttime, or in locations with low light levels. A press of any area on the

Page 17

STATIC NOTICE: This thermostat is protected against normal static electricdischarges, however to minimize the risk of damaging the unit in extremely d

Page 18

and DOWN buttons, select the day that you want to copy from. Press the NEXTbutton one time. Your copy from day should now be on steady with the day

Page 19

second heating stage to turn on. This setting can be used to conserve energy insituations where the second heating stage is more costly to operate wh

Page 20

TEMPERATURE CALIBRATION DESCRIPTION: The internal temperature sensor inthis thermostat is accurately calibrated at the factory, and in most cases,alte

Page 21

NOTE: The Setback settings need to be performed in a timely manner, as thethermostat will timeout and automatically exit these adjustment screens afte

Page 22 - EMER. = ON

The following examples are shown for setting the maximum set temperature forHeat mode. Setting the Temperature Limit Stop for Cool mode is done in th

Page 23 - HOLD = ON

MENUF˚F˚SETPMHEATOFFCOOLAUTOONFA NTX9600TSaSet TemperatureRoom TemperatureFanModeSwitchSystemModeSwitchMenuButtonClockThe electrical rating for this t

Page 24

KEYPAD LOCKOUT: You can lock the touch-panel buttons to prevent unauthorizedtampering of your thermostat settings.NOTE: These keypad lock instructions

Page 25

The Air Filter Monitor counts the duration of filter usage that has occurred, sincethe last time the Filter Monitor has been reset. This feature is f

Page 26 - ** = Only applies if a second

for viewing the Energy Usage while in Heat mode. Viewing the Cool modeinformation is done in the same exact manner in Cool mode.TO VIEW THE ENERGY US

Page 27

COMPRESSOR PROTECTION BYPASS: This optional feature permits the installeror service technician to temporarily disable the built in compressor protecti

Page 28

If you have any problems installing or using this thermostat, please carefully andthoroughly review the instruction manual. If you require assistance,

Page 29

35Mt. Laurel, New Jersey 08054, USAhttp://www.luxproducts.com 856-234-8803MENUF˚F˚SETPMHEATOFFCOOLAUTOONFA N

Page 30

• 1 or 2-Heat / 1-Cool, 7-day programming• Universal Compatibility for all system types• Each day of the week can be programmed separately• Easy to us

Page 31

On replacement installations, mount the new thermostat in place of the old oneunless the conditions listed below suggest otherwise. On new installati

Page 32

1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean offany corrosion present.2. Fill the wall opening with non-combustible

Page 33

CONNECTING THE WIRES:When attaching the wires to the thermostat, please ensure that the bare wireends are held ALL the way into the terminal block whi

Page 34

WIRING DIAGRAM NOTES:(Important, please read all notes before connecting wires)• If the information provided in the following wiring diagrams does not

Page 35 - 856-234-8803

9#1 CONVENTIONAL: HEATING ...............101-STAGE OR 2-STAGE2, 3, 4, 5 WIRES#2 CONVENTIONAL: HEATING ...

Commentaires sur ces manuels